0531-6667 8888

NCB40-FP-A2-P1-3G-3D

40 mm flush4-wire DCATEX-approval for zone2 and zone22

重要参数:

系列: Rectangular type

外壳材料:PBT

输出及电压类型:4 线,DC

输出:PNP

40 mm flush

4-wire DC

ATEX-approval for zone 2 and zone 22


General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance40 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 32.4 mm
Reduction factor rAl0.25
Reduction factor rCu0.23
Reduction factor r3040.85
Output type4-wire
Nominal ratings
Operating voltage10 ... 60 V DC
Switching frequency0 ... 80 Hz
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity protected
Voltage drop≤ 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA
No-load supply current≤ 20 mA
Time delay before availability≤ 300 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd630 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity

StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2 , stripped insulation length: 7 mm

Minimum core cross-sectionmin. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors)

Maximum core cross-sectionmax. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors)
Connection (system side)screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm
Housing materialPBT
Sensing facePBT
Housing basePBT
Degree of protectionIP68
General information
Use in the hazardous areasee instruction manuals