0531-6667 8888

NCN50-FP-A2-P1-3G-3D

50 mm non-flush4-wire DCATEX-approval for zone2 and zone22

重要参数:

系列:Rectangular type

外壳材料:PBT

输出及电压类型:4 线,DC

输出:PNP

50 mm non-flush

4-wire DC

ATEX-approval for zone 2 and zone 22


General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance50 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 40.5 mm
Reduction factor rAl0.4
Reduction factor rCu0.3
Reduction factor r3040.85
Output type4-wire
Nominal ratings
Operating voltage10 ... 60 V DC
Switching frequency0 ... 80 Hz
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity protected
Voltage drop≤ 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA
No-load supply current≤ 20 mA
Time delay before availability≤ 300 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd671 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity

StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2 , stripped insulation length: 7 mm

Minimum core cross-sectionmin. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors)

Maximum core cross-sectionmax. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors)
Connection (system side)screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm
Housing materialPBT
Sensing facePBT
Housing basePBT
Degree of protectionIP67
General information
Use in the hazardous areasee instruction manuals